Modern HVACR equipment relies on digital controls, software, communication interfaces and remote services. These features improve efficiency and maintenance, but they can also create opportunities for cyberattacks.
The EU Cyber Resilience Act (CRA) establishes cybersecurity requirements for products with digital elements made available on the EU market. For HVACR manufacturers, this means considering cybersecurity throughout the product lifecycle—from design and production to security updates, vulnerability handling and the end of support.
The immediate message for manufacturers: identify which products are in scope, understand your reporting obligations, and prepare the product designs, documentation and support processes needed for compliance.
Key dates
- 11 September 2026: Manufacturer reporting obligations for actively exploited vulnerabilities and severe security incidents apply.
- 11 December 2027: Most other CRA requirements apply.
Reporting obligations also cover in-scope products placed on the market before 11 December 2027. European Commission: CRA summary
Why the CRA matters for HVACR
HVACR products increasingly connect to building automation systems, mobile apps, cloud platforms, service tools and other devices. A vulnerability in a controller or communication interface can affect the equipment itself and may also expose connected systems.
For example, an attacker who gains access to a refrigeration controller could alter settings, interrupt operation or use the device as a route into a wider network. In its interview on the CRA, Eurovent highlights the operational and financial consequences of an attack on supermarket refrigeration controls. Eurovent: A look at the Cyber Resilience Act
The CRA makes cybersecurity relevant to more than software teams. Product management, engineering, procurement, quality, legal, customer support and service teams all have a role.
From product delivery to lifecycle responsibility
Assess → Design → Verify → Place on the market → Monitor → Update → End support
A manufacturer must be able to demonstrate that the product meets applicable cybersecurity requirements and that the manufacturer can handle vulnerabilities during the stated support period.
Which HVACR products may be covered?
The CRA applies broadly to hardware and software products with digital elements that are made available on the EU market and have a direct or indirect logical or physical data connection to a device or network. Some products and circumstances are excluded or covered by specific rules, so scope must be assessed individually. A product does not need an internet connection to warrant assessment.
| HVACR product or feature | Why it should be assessed | Example |
|---|---|---|
| Connected HVACR equipment | Embedded software and a data interface may bring the product within scope. | A heat pump with Ethernet, Wi-Fi or a building automation connection |
| Controllers and thermostats sold separately | A separately marketed digital component can itself be a product with digital elements. | A programmable room controller sold as an accessory |
| Building automation gateways | Gateways exchange data between devices, networks or services. | A gateway connecting HVAC units to a building management system |
| Refrigeration controls | Controllers may communicate with local equipment, monitoring systems or service platforms. | A controller connected to temperature sensors and a remote monitoring service |
| Service or commissioning interfaces | A local physical or wireless interface can be relevant even without internet access. | A service port or Bluetooth commissioning interface |
| Software sold or supplied separately | Standalone software may be a product with digital elements in its own right. | A commercial configuration or monitoring application |
| Cloud functionality | A remote data processing solution may be relevant where the product depends on it to perform a function. | A manufacturer-operated remote management service |
| Equipment without a data connection | Assess its actual design and use before deciding it is outside scope. | A purely mechanical component with no digital data connection |
Start with a product inventory. For every product and separately marketed component, record its digital functions, software, physical and wireless interfaces, intended users, connected services, and how it is placed on the market. Document the scope decision and the reasons for it.
Assess the complete product. A component supplier’s conformity information is useful, but the manufacturer of the final product remains responsible for assessing its own product and the way integrated components work together.
The inclusion of a component listed as an “important product” in Annex III does not automatically make the finished HVACR product an important product. Classification depends on the finished product’s own core functionality and the applicable legal criteria. CRA, Articles 2, 3 and 7 and Annex III
What about products already on the market?
The date an individual product is first placed on the EU market matters. Under the CRA’s transitional provisions, products placed on the market before 11 December 2027 generally become subject to the main requirements if they undergo a substantial modification from that date. Article 14 reporting obligations nevertheless apply to in-scope products placed on the market before that date.
A product model first sold before the deadline does not automatically exempt every later unit: assess when each product is placed on the market and whether a change qualifies as a substantial modification. CRA, Articles 69 and 71
What manufacturers need to do
The CRA requires an appropriate level of cybersecurity based on the risks associated with the product. Manufacturers must document a cybersecurity risk assessment and use it throughout planning, design, development, production, delivery and maintenance.
The table below translates the main product requirements into HVACR examples. The examples are practical design measures; the correct implementation depends on the product and its documented risk assessment.
| Area | CRA requirement | Practical HVACR example |
|---|---|---|
| Risk assessment | Assess and document risks based on intended use, reasonably foreseeable use and the operating environment; update the assessment as appropriate during support. | Assess remote service access, exposed communication ports, controller tampering and the consequences of losing temperature control. |
| Known vulnerabilities | Place the product on the market without known exploitable vulnerabilities. | Review the firmware and included components for known exploitable issues before release. |
| Secure default configuration | Provide secure default settings, including the ability to reset to the original state, subject to the regulation’s tailored business-product exception. | Disable unnecessary services and require appropriate setup of administrator access during commissioning. |
| Access control | Protect against unauthorised access using appropriate mechanisms and report possible unauthorised access. | Use appropriate authentication and access permissions for installers, service technicians and building operators. |
| Security updates | Make vulnerabilities addressable through security updates. Where applicable, automatic security updates are enabled by default, with notification, an easy opt-out and an option to postpone temporarily. | Provide an authenticated update mechanism and a clear process for installing controller firmware updates during suitable maintenance windows. |
| Confidentiality | Protect the confidentiality of relevant stored and transmitted data using appropriate, state-of-the-art mechanisms. | Protect credentials and sensitive service communications. |
| Integrity | Protect data, commands, programs and configuration from unauthorised changes and report corruption. | Verify firmware integrity and protect control settings against unauthorised modification. |
| Availability | Protect the availability of essential and basic functions, including after an incident. | Consider safe, resilient operation if a controller loses its network or cloud connection. |
| Attack surface | Limit attack surfaces, including external interfaces, and reduce the impact of incidents. | Close unused network ports and restrict diagnostic interfaces according to assessed risk. |
| Logging and monitoring | Provide security-related information by recording and monitoring relevant internal activity, with a user opt-out mechanism. | Record relevant access attempts and changes to security settings where appropriate. |
| Data minimisation and removal | Limit data processing to what is necessary and enable secure, easy, permanent removal of data and settings. | Provide a secure reset and decommissioning procedure before equipment is resold or disposed of. |
| Connected systems | Minimise the product’s negative impact on the availability of other devices or networks. | Test how the controller behaves when communication fails or traffic is abnormal. |
Not every technical measure applies identically to every product. Manufacturers must document how relevant Annex I requirements are met and provide a clear justification where a requirement is not applicable. CRA, Article 13 and Annex I
Design for the realities of HVACR operation
Equipment may operate for many years in buildings where updates require coordination with operators and service companies. Consider these questions early:
- Can security updates be installed safely without unnecessarily interrupting heating, cooling or refrigeration?
- What happens if an update fails or power is lost?
- Can installers identify the software version and the correct update?
- Can access be restricted when a service technician’s work is complete?
- Can the product maintain essential functions when a network or remote service is unavailable?
- Can the operator remove credentials, settings and data at decommissioning?
These are design and testing prompts; the CRA does not prescribe one universal solution for every HVACR system.
Product displays, labels and customer information
Manufacturers often ask whether the CRA requires a dedicated cybersecurity screen on every unit. It does not prescribe a universal screen layout or a cybersecurity dashboard for all products. It does, however, require specific information to be provided to users and, where technically feasible, an end-of-support notification.
What must be shown or supplied?
| Information | What the manufacturer must do | Where or how |
|---|---|---|
| Product identification | Ensure the product bears a type, batch or serial number, or another identifying element. | On the product; where that is not possible, on its packaging or in an accompanying document. |
| Manufacturer contact details | Provide the manufacturer’s name or registered trade name or trademark, postal address, email or other digital contact, and website where applicable. | On the product, packaging or an accompanying document; also include the details in the user information. |
| Security support end date | Clearly specify the end date, including at least month and year, in an easily accessible manner at the time of purchase. | Where applicable, on the product, its packaging or by digital means. It must also be included in the accompanying user information. |
| End-of-support notification | Inform users when the product has reached the end of its support period, where technically feasible given the product’s nature. | The CRA does not prescribe one universal display format. A suitable on-device or digital notification can be considered according to the product. |
| Vulnerability reporting contact | Provide an easily identifiable single point of contact so users can communicate directly and rapidly, including to report vulnerabilities. | Include it in the accompanying information and instructions. Users must be able to choose their preferred communication method; contact cannot be limited to automated tools. |
| Instructions for secure use | Supply clear and understandable information that enables secure installation, operation and use. | Paper or electronic form; include the information or links required by Annex II. |
| EU declaration of conformity | Supply the full declaration or a simplified declaration with the product. | A simplified declaration must include the exact internet address of the full declaration. |
| CE marking | Affix the CE marking before placing the product on the market, after the applicable conformity assessment has demonstrated compliance. | Visibly, legibly and indelibly on the product. If this is impossible or unwarranted because of the product’s nature, apply the Article 30 alternative for packaging and the accompanying declaration. |
Instructions and contact information must be understandable to users and market surveillance authorities. Where information is supplied online, it must remain accessible and user-friendly for at least 10 years after the product is placed on the market or for the support period, whichever is longer. CRA, Articles 13 and 30 and Annex II
Example: product information screen
The following is an illustrative design, not a mandatory CRA screen or prescribed wording:
Product information
Model: HVAC Controller X100
Software version: 2.4.1
Security support until: December 2032
Security updates: Available
Report a security issue: manufacturer contact details
Product instructions and EU declaration: manufacturer website
Use the actual product model, support date, contact details and links. The purchase-stage support information and accompanying documentation still need to be provided as required; an on-device screen alone does not necessarily meet those obligations.
Example: end-of-support message
Security support has ended
The manufacturer’s security support period for this product ended in December 2032. Security updates may no longer be provided. Contact the manufacturer or your service provider to discuss available options.
This is suggested wording. The correct delivery method and message should reflect the product, its users and the manufacturer’s actual support arrangements.
What should the user instructions include?
At a minimum, review Annex II and provide the information applicable to the product, including:
- Manufacturer and vulnerability-reporting contact details, and where to find the coordinated vulnerability disclosure policy.
- Product name, type and information needed to identify it.
- Intended purpose, essential functions, security properties and the security environment provided by the manufacturer.
- Known or foreseeable circumstances that may lead to significant cybersecurity risks.
- The type of technical security support and the end date of the support period.
- Secure commissioning and operation instructions, including how security-relevant updates are installed.
- How changes to the product can affect data security.
- Secure decommissioning and removal of user data.
- How to turn off default automatic security updates, where the relevant requirement applies.
- Information needed by an integrator when the product is intended for integration into another digital product.
- Where applicable, the internet address of the declaration of conformity and, if the manufacturer chooses to make the software bill of materials available to users, where to access it.
For sales teams: make the security support end date easy to find before the purchase is completed—for example, in a clearly visible product specification or quotation. The precise format is a business decision, but the legal requirement is to make the date clear and easily accessible at the time of purchase.
Security support and updates
How long must security support last?
The manufacturer must determine and document a support period based on factors set out in the CRA, including the expected use, the product’s nature and relevant dependencies.
The period must generally be at least five years. If the product is expected to be in use for less than five years, the support period corresponds to that expected use time. Five years is a minimum rule, not an automatic justification for a five-year period for every long-life HVACR product.
During the support period, manufacturers must handle vulnerabilities effectively. They must make security updates available without delay and generally free of charge; the CRA provides an exception for an agreement between a manufacturer and a business user concerning a tailor-made product.
Each security update made available during the support period must remain available for at least 10 years after it is issued or for the remainder of the support period, whichever is longer. CRA, Article 13 and Annex I, Part II
Build a vulnerability-handling process
A practical process should be able to:
- Receive reports from users, researchers, suppliers and internal teams.
- Identify affected products and versions, including third-party components.
- Assess and remediate vulnerabilities without delay in proportion to the risks.
- Test and distribute fixes securely, with relevant advice to users.
- Report qualifying cases to the authorities within the applicable deadlines.
- Publish information on fixed vulnerabilities as required, with the CRA’s limited provision for delayed disclosure in duly justified cases.
- Keep records of decisions, testing, releases and communications.
Manufacturers must also maintain a coordinated vulnerability disclosure policy and prepare a software bill of materials (SBOM) in a commonly used, machine-readable format covering at least the product’s top-level dependencies. The CRA does not generally require the SBOM to be published to all customers. CRA, Annex I, Part II
When must a manufacturer report to authorities?
Since 11 September 2026, manufacturers must report:
- Actively exploited vulnerabilities contained in an in-scope product; and
- Severe incidents that affect the security of an in-scope product.
Reports are submitted through the ENISA Single Reporting Platform, which makes them available to the designated national CSIRT coordinator and ENISA.
| Stage | Deadline | What it means |
|---|---|---|
| Early warning | Without undue delay and within 24 hours of becoming aware | Submit the initial information required by Article 14. |
| Vulnerability or incident notification | Without undue delay and within 72 hours of becoming aware | Provide the required available information, unless it has already been supplied. |
| Final report: actively exploited vulnerability | No later than 14 days after a corrective or mitigating measure is available | Include the required description, impact and available remedy information. |
| Final report: severe incident | Within one month after submitting the incident notification | Include the required incident description, likely cause and mitigation measures. |
The 24-hour and 72-hour clocks run from when the manufacturer becomes aware. Article 14 defines when an incident is considered severe; not every vulnerability or operational fault is automatically reportable under these provisions.
Manufacturers must also inform affected users, and where appropriate all users, about an actively exploited vulnerability or severe incident and, where necessary, about measures users can take. CRA, Article 14; European Commission: CRA reporting summary
Prepare now: assign a reporting owner and backup, establish an escalation route outside normal business hours, and ensure the relevant staff know how to use the reporting platform.
Conformity assessment, technical documentation and CE marking
Before placing an in-scope product on the market under the applicable requirements, the manufacturer must prepare technical documentation, complete the appropriate conformity assessment and, once compliance has been demonstrated, draw up an EU declaration of conformity and affix the CE marking.
Which assessment route applies?
| Product classification | General route to check |
|---|---|
| Product not classified as important or critical | The CRA generally permits conformity assessment based on internal control, subject to the applicable rules. |
| Important product: Class I | Internal control is available when the relevant requirements are covered through the applicable harmonised standards, common specifications or qualifying certification route. Otherwise, the Article 32 third-party assessment routes apply. |
| Important product: Class II | Article 32 generally requires the specified third-party conformity assessment routes, subject to the regulation’s applicable certification provisions. |
| Critical product | Check Annex IV and Article 8 for applicable certification requirements and the relevant assessment route. |
Classification depends on the product’s core functionality and current implementing measures—not simply on whether it is connected. Check the latest legal text and guidance before selecting a route. CRA, Articles 7, 8 and 32 and Annexes III and IV
What belongs in the technical documentation?
Annex VII specifies the required contents, as applicable. For an HVACR manufacturer, the file will typically need to bring together:
- Product description, intended purpose and software versions relevant to compliance.
- Architecture, design, development and production information.
- The documented cybersecurity risk assessment and explanations of how applicable requirements are met.
- Information on vulnerability handling, including relevant processes and the support-period determination.
- Applied standards, common specifications or other technical solutions, and relevant test results.
- User information and instructions.
- The declaration of conformity and, where applicable, assessment or certificate information.
Keep the technical documentation and EU declaration available to market surveillance authorities for at least 10 years after the product is placed on the market or the support period, whichever is longer.
The CE marking is a visible outcome of the conformity process. If other applicable EU legislation also requires a declaration of conformity, a single EU declaration is drawn up covering the relevant acts. CRA, Articles 13, 28, 30 and 31 and Annex VII
What about standards?
Harmonised standards can help manufacturers demonstrate conformity when their references are published for that purpose in the Official Journal of the European Union and the relevant conditions are met. A published standard does not automatically provide a presumption of conformity simply because it is described as supporting the CRA.
The European Commission reported publication of the first European standard supporting CRA implementation in November 2026; further standards are in development. Check the current status, scope and Official Journal references before relying on any standard for conformity. European Commission: CRA standardisation; European Commission: first European standard
Example: connected air-handling unit
Product: An air-handling unit with an embedded controller, a building automation interface and remote service access.
| Stage | Questions and actions |
|---|---|
| Scope | Identify the unit, separately sold controller and any relevant software or remote processing service. Document which products are in scope. |
| Risk assessment | Assess building network connections, service access, credentials, update paths and the consequences of unauthorised changes to operation. |
| Design | Apply risk-appropriate access controls, secure defaults, update protection and measures to maintain essential functions. |
| Supply chain | Identify firmware libraries and supplier components; agree how vulnerability information and fixes will be communicated. |
| Documentation | Prepare the technical file, applicable user instructions, product identification and support information. |
| Market access | Determine classification and assessment route, complete conformity assessment, prepare the declaration and apply CE marking. |
| After sale | Monitor vulnerabilities, deliver security updates, inform users and report qualifying cases within the legal deadlines. |
| End of support | Provide the end date at purchase and in user information; display an end-of-support notification where technically feasible. |
Manufacturer checklist
1. Identify and assess
- List HVACR equipment, controllers, gateways, apps and relevant services.
- Record data connections, software versions and third-party components.
- Document the CRA scope and classification decision for each product.
- Assess intended use, foreseeable misuse and operational environment.
- Identify risks to equipment, connected systems, users and essential functions.
2. Secure the product
- Apply the relevant Annex I cybersecurity requirements.
- Review default settings, authentication and service access.
- Protect relevant data, commands, configuration and update mechanisms.
- Assess operational resilience and safe update procedures.
- Test security regularly and document results.
- Explain and document any requirement assessed as not applicable.
3. Prepare for the market
- Determine and document the security support period.
- Prepare the technical documentation and required user information.
- Ensure product identification and manufacturer contact details are supplied.
- Make the support end date clear and accessible at the time of purchase.
- Complete the applicable conformity assessment.
- Draw up the EU declaration of conformity and affix CE marking.
- Plan the end-of-support notification where technically feasible.
4. Support products after sale
- Maintain a machine-readable SBOM covering at least top-level dependencies.
- Operate a coordinated vulnerability disclosure policy and contact point.
- Monitor and remediate product and component vulnerabilities.
- Distribute security updates and user advice as required.
- Prepare to report actively exploited vulnerabilities and severe incidents.
- Retain documentation, instructions and updates for the applicable periods.
Frequently asked questions
Does the CRA apply only to products connected to the internet?
No. A direct or indirect data connection to another device or network can be relevant. Assess local interfaces and device-to-device communication as well as internet, app and cloud connections.
Does every HVACR product need a cybersecurity display?
No universal cybersecurity display is prescribed. However, the CRA requires certain information to be supplied and requires an end-of-support notification where technically feasible in light of the product’s nature.
Is an existing CE mark enough?
The manufacturer must assess compliance with all applicable legislation. When the CRA’s applicable requirements take effect for the product, the conformity assessment and declaration must cover those requirements as well as other relevant EU legislation.
Does a supplier’s compliant controller make the whole HVACR unit compliant?
No automatic conclusion follows. The manufacturer of the final product must assess the final product, its integration and its own obligations. Supplier evidence is an important input to that assessment.
Must manufacturers report every vulnerability?
Article 14 specifically requires reporting of actively exploited vulnerabilities and severe incidents affecting product security. Manufacturers also have separate obligations to identify, assess and remediate vulnerabilities during the support period.
Are security updates always automatic?
The CRA requires vulnerabilities to be addressable through security updates. Automatic security updates enabled by default are required where applicable, with a clear and easy opt-out, update notification and an option to postpone temporarily. Assess the requirement against the product and document the implementation.
Does the CRA replace other HVACR requirements?
No. Other EU product, safety, radio, environmental, data protection or sector-specific rules may also apply. Assess the complete set of legislation relevant to each product.
Sources and further reading
- Regulation (EU) 2024/2847: Cyber Resilience Act — official legal text
- European Commission: CRA summary and manufacturer obligations
- European Commission: practical CRA guidance
- European Commission: CRA standardisation
- ENISA: CRA Single Reporting Platform
- Eurovent: A look at the Cyber Resilience Act with Tianyun Gao
Leave a Reply